8. Under the DSView heading, enter the IP address of the DSView 3 server where event notifications will be
sent in the DSView 3 server field. Enter the syslog server port number for the DSView 3 server, the SSH
information and the buffer warning information in the appropiate fields.
9. Click Save.
Trap Forward
The console server will receive SNMP traps and forward them to a remote SNMP trap server.
To add a SNMP trap server to forward traps:
1. Click Events and Logs – Trap Forward.
2. Click Add.
3. Enter the IP address of the remote server and the UDP port.
4. Enter the OID to filter traps to send to this server (optional).
To edit SNMP trap server configuration:
1. Click Events and Logs – Trap Forward.
2. Click the index of the server to be edited.
3. Update the UDP port and/or the OID and click Save.
Data Buffering
To configure Data Buffering:
1. Select Events and Logs - Data Buffering.
2. Enter the segment size in kilobytes and spare segments in the Local Data Buffering Settings section.
3. In the NFS Data Buffering Settings section, enter the following information: NFS Server, NFS Path, Segment
Size (Kbytes) and Spare Segments.
NOTE: RPC service must be enabled in the Security Profile screen before configuring NFS Data Buffering Settings. NFS does not
support IPv6.
4. To segment data buffering files every day based in hour, enter the time in the Close Log Files and Open
New Ones at Time (HH:MM) field. This will be valid for local and NFS data buffering.
5. To configure data buffer storage on a syslog server in the Syslog Data Buffering Settings section; select a
facility number from the drop-down menu: Log Local 0, Log Local 1, Log Local 2, Log Local 3, Log Local
4 or Log Local 5.
6. Click Save.
Appliance logging
To configure appliance logging:
1. Click Enable appliance session data logging.
52 Cyclades™ ACS 6000 Advanced Console Server