Parameter Description
PPP Idle
Timeout
Number of seconds being idle before PPP times out. Default: 0 (no time-out).
To configure or to edit one or more serial ports with a connected PDU:
1. Select Ports - Serial Ports.
2. Click the checkbox for one or more serial ports with a connected PDU.
3. Click the Set Power button and use the drop-down menus to configure the physical settings.
4. Click Next or click the Power link.
a. Use the drop-down menu to select the PDU type.
b. Check the box to enable speed auto detection.
c. Configure the polling rate.
d. For Avocent/Cyclades PDUs, enter the power cycle interval and then use the drop-down menus to
enable or disable Syslog, Buzzer and SW Overcurrent Protection.
5. Click Save.
Parameter Description
Physical
Enable Cisco RJ-45 Pin-
Out
Defines the serial port pinout. Default: Disabled.
Status Defines the status of the serial port as either enabled or disabled. Default: Disabled.
Speed
Defines the speed as 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600 or 115200.
Default: 9600.
Parity Defines the parity as either Even, Odd or None. Default: None.
Data Bits
Defines the data bits as either 5, 6, 7 or 8. Default: 8.
Stop Bits Defines the stop bits as either 1 or 2. Default: 1.
Flow Control
Defines the flow control as none, hardware, software, RxON software or TxON sofware.
Default: None.
Power
PDU Type
Defines the type or vendor of the PDU connected to the serial port.
• Auto - the vendor will be detected.
• Avocent-Cyclades - Avocent-Cyclades PM PDU family.
• SPC - SPC power control device family.
• Server Tech - Server Tech family.
Default: Auto.
Enable Speed Auto
Detection
When enabled, detects the speed of the port. Default: Disabled.
Pooling Rate The interval in seconds to update information from the PDU. Default: 20.
For Avocent/Cyclades
PDUs
Power Cycle Interval
The interval in seconds between Off and On actions for the power cycle command. Default:
15.
Syslog When enabled, the PDU will send syslog messages to the appliance. Default: Enabled.
Buzzer Enables or disables the PDU’s buzzer. Default: Enabled.
SW Overcurrent Protection
When enabled, the software’s overcurrent protection is on. Default: Disabled.
Table 3.7: Power Parameters
34 Cyclades™ ACS 6000 Advanced Console Server